饱和蒸汽表(按压力或温度查饱和水、饱和蒸汽物性)

输入压力(表压或绝对压力)或温度,即按 IAPWS-IF97 求出饱和温度或压力、比容、焓(h_f、h_fg、h_g)和熵。下方附有实务中常查的压力、温度间隔表。

按压力的饱和蒸汽表(表压 0 ~ 20 bar)

按表压加标准大气压 101.325 kPa 的绝对压力计算。f 为饱和水,g 为饱和蒸汽,fg 为汽化(g − f)。粗体行为大气压(0 bar(G))。表格较宽时可左右滑动。

表压 bar(G)绝对压力 kPa饱和温度 °Cvf m³/kgvg m³/kghf kJ/kghfg kJ/kghg kJ/kgsf kJ/(kg·K)sg kJ/(kg·K)
0101.3399.970.00104341.6733419.02,256.52,675.51.30677.3544
0.5151.33111.610.00105291.1499468.22,225.32,693.51.43657.2200
1201.33120.420.00106070.88028505.62,201.02,706.51.53247.1247
1.5251.33127.590.00106740.71515536.12,180.72,716.71.60917.0506
2301.33133.680.00107330.60329562.12,163.02,725.11.67336.9901
2.5351.33138.990.00107870.52234584.92,147.32,732.11.72886.9388
3401.33143.730.00108370.46096605.22,133.02,738.21.77786.8943
3.5451.33148.020.00108830.41276623.72,119.82,743.51.82176.8550
4501.33151.940.00109270.37387640.62,107.62,748.21.86166.8197
4.5551.33155.550.00109680.34181656.32,096.22,752.41.89826.7877
5601.33158.920.00110070.31492670.92,085.42,756.21.93206.7584
6701.33165.030.00110810.27228697.52,065.42,762.81.99286.7063
7801.33170.480.00111490.23995721.32,047.12,768.42.04676.6610
8901.33175.420.00112130.21457743.02,030.12,773.12.09506.6207
91,001.3179.940.00112730.19410762.92,014.22,777.22.13906.5845
101,101.3184.120.00113310.17723781.41,999.32,780.72.17946.5516
111,201.3188.010.00113860.16308798.71,985.12,783.82.21686.5213
121,301.3191.660.00114390.15103815.01,971.62,786.52.25166.4933
131,401.3195.090.00114900.14064830.31,958.62,788.92.28436.4672
141,501.3198.340.00115390.13159844.91,946.12,791.02.31516.4427
151,601.3201.420.00115870.12363858.81,934.12,792.92.34426.4197
161,701.3204.350.00116340.11658872.11,922.52,794.62.37186.3980
181,901.3209.840.00117240.10463897.01,900.32,797.32.42336.3577
202,101.3214.900.00118110.094875920.11,879.22,799.42.47046.3210

按温度的饱和蒸汽表(0.01 ~ 200 °C)

0.01 °C 为水的三相点。100 °C 以下间隔 5 °C,以上间隔 10 °C。压力为绝对压力,粗体行为 100 °C。

温度 °C饱和压力 kPavf m³/kgvg m³/kghf kJ/kghfg kJ/kghg kJ/kgsf kJ/(kg·K)sg kJ/(kg·K)
0.010.611660.0010002206.000.02,500.92,500.90.00009.1555
50.872570.0010001147.0221.02,489.12,510.10.07639.0249
101.22820.0010003106.3142.02,477.22,519.20.15118.8998
151.70570.001000977.88163.02,465.42,528.40.22458.7804
202.33920.001001857.76183.92,453.52,537.50.29658.6661
253.16970.001003043.341104.82,441.72,546.50.36738.5568
304.24670.001004432.882125.72,429.82,555.60.43688.4521
355.62860.001006025.208146.62,417.92,564.60.50528.3518
407.38440.001007919.517167.52,406.02,573.50.57248.2557
459.59440.001009915.253188.42,394.02,582.50.63868.1634
5012.3510.001012112.028209.32,382.02,591.30.70388.0749
5515.7610.00101459.5649230.22,369.92,600.10.76807.9899
6019.9460.00101717.6677251.22,357.72,608.80.83127.9082
6525.0410.00101996.1938272.12,345.42,617.50.89357.8296
7031.2010.00102285.0397293.02,333.12,626.10.95507.7540
7538.5950.00102584.1291314.02,320.62,634.61.01567.6812
8047.4150.00102903.4053334.92,308.12,643.01.07547.6110
8557.8670.00103242.8259355.92,295.42,651.31.13447.5434
9070.1820.00103592.3591377.02,282.62,659.51.19277.4781
9584.6090.00103961.9806398.02,269.62,667.61.25027.4150
100101.420.00104351.6719419.12,256.52,675.61.30707.3541
110143.380.00105161.2094461.42,229.72,691.11.41877.2380
120198.670.00106030.89130503.82,202.12,705.91.52787.1291
130270.260.00106970.66808546.42,173.72,720.11.63467.0264
140361.500.00107980.50852589.22,144.22,733.41.73936.9293
150476.100.00109050.39250632.32,113.72,745.91.84206.8370
160618.140.00110200.30682675.62,081.92,757.41.94286.7491
170792.050.00111430.24262719.22,048.72,767.92.04196.6649
1801,002.60.00112740.19386763.22,014.02,777.22.13956.5841
1901,255.00.00114140.15638807.61,977.72,785.32.23586.5060
2001,554.70.00115650.12722852.41,939.72,792.12.33086.4303

验证:与公开资料对比

将 IAPWS-IF97 官方文件中的验算值和教材饱和蒸汽表的数值与本页计算值并列。教材表基于 IAPWS-95,与 IF97 相差约 0.02 %。若超出允许误差,本页不会生成(构建失败)。

项目公开资料值计算器值依据
T = 300 K
p_sat3.53658941 kPa3.536589413 kPaIAPWS R7-97(2012) 程序验算值
T = 500 K
p_sat2,638.89776 kPa2,638.897756 kPaIAPWS R7-97(2012) 程序验算值
p = 1 MPa
T_sat453.035632 K453.0356324 KIAPWS R7-97(2012) 程序验算值
γ₁: T = 300 K, p = 3 MPa
v0.00100215168 m³/kg0.0010021517 m³/kgIAPWS R7-97(2012) 程序验算值
h115.331273 kJ/kg115.3312730 kJ/kgIAPWS R7-97(2012) 程序验算值
s0.392294792 kJ/(kg·K)0.3922947924 kJ/(kg·K)IAPWS R7-97(2012) 程序验算值
γ₂: T = 300 K, p = 0.0035 MPa
v39.4913866 m³/kg39.49138664 m³/kgIAPWS R7-97(2012) 程序验算值
h2,549.91145 kJ/kg2,549.911451 kJ/kgIAPWS R7-97(2012) 程序验算值
s8.52238967 kJ/(kg·K)8.522389667 kJ/(kg·K)IAPWS R7-97(2012) 程序验算值
T = 100 °C
p_sat101.42 kPa101.418 kPaÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
h_fg2,256.4 kJ/kg2,256.47 kJ/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
h_g2,675.6 kJ/kg2,675.57 kJ/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
s_g7.3542 kJ/(kg·K)7.35408 kJ/(kg·K)Çengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
T = 180 °C
p_sat1,002.8 kPa1,002.63 kPaÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
v_g0.19384 m³/kg0.193862 m³/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
h_g2,777.2 kJ/kg2,777.22 kJ/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
p = 1,000 kPa
T_sat179.88 °C179.886 °CÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
h_fg2,014.6 kJ/kg2,014.44 kJ/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)
h_g2,777.1 kJ/kg2,777.12 kJ/kgÇengel、Boles《Thermodynamics》饱和蒸汽表(附录表 A-4、A-5)

计算依据

直接用工业国际标准 IAPWS-IF97 计算。饱和压力和温度用区域 4 公式,饱和水和饱和蒸汽分别把 (T_sat, p_sat) 代入区域 1、区域 2 的吉布斯自由能方程。系数直接取自 IAPWS 官方文件的表。

项目公式备注
绝对压力p_abs = p_g + 101.325 kPa表压时加上标准大气压 101.325 kPa
饱和压力p_sat = [2C / (−B + √(B² − 4AC))]⁴区域 4 式 (30)。θ = T + n₉/(T − n₁₀),A、B、C 为 θ 的二次式
饱和温度T_sat = [n₁₀ + D − √((n₁₀ + D)² − 4(n₉ + n₁₀D))] / 2区域 4 式 (31)。式 (30) 的精确反函数,β = p^0.25
饱和水(区域 1)γ₁ = Σ nᵢ (7.1 − π)^Iᵢ (τ − 1.222)^Jᵢ式 (7)。π = p / 16.53 MPa,τ = 1386 K / T,34 个系数
饱和蒸汽(区域 2)γ₂ = ln π + Σ n°ᵢ τ^J°ᵢ + Σ nᵢ π^Iᵢ (τ − 0.5)^Jᵢ式 (15)。π = p / 1 MPa,τ = 540 K / T,理想气体系数 9 个 + 剩余系数 43 个
比容、焓、熵v = π γ_π RT/p, h = τ γ_τ RT, s = R(τ γ_τ − γ)γ 对 π、τ 的偏导数,R = 0.461526 kJ/(kg·K)
汽化h_fg = h_g − h_f, s_fg = s_g − s_f汽化潜热和汽化熵

范围与基准

范围从水的三相点 0.01 °C(0.6117 kPa)到 350 °C(16.53 MPa)。IF97 区域 1、2 的公式适用到 350 °C(623.15 K),其上至临界点 373.946 °C 的区域 3 不在本工具范围内。空调和蒸汽设备的压力都在此范围内。

焓和熵的零点为三相点饱和水的内能和熵,所以 0.01 °C 饱和水的 h_f 是 0.0006 kJ/kg 而不是 0。末位可能与教材表(IAPWS-95)不同,原因是两套公式的差异(饱和压力约 0.02 %)和四舍五入。

蒸汽管和凝结水回水管计算使用以同一 IF97 值预先算好的压力表插值,两者相差不到 0.005 %,在显示位数上相同。

出处

常见问题

已知压力,怎样查饱和温度和汽化潜热?

在上方计算器选择「压力」,输入数值、表压或绝对压力及单位即可得到。例如 7 bar(G)(绝对 8.013 bar)的饱和温度为 170.5 °C,汽化潜热 h_fg 为 2,047 kJ/kg。按压力的表中也能看到相同数值。

应该用表压还是绝对压力查?

蒸汽表中的压力为绝对压力。现场压力表显示的是表压,需加上大气压 101.325 kPa(1.013 bar)。本计算器选择「表压」时自动相加。0 bar(G) 即绝对 101.325 kPa,饱和温度 99.97 °C。

压力升高时汽化潜热为什么减小?

压力升高时,饱和水焓 h_f 迅速增大,而饱和蒸汽焓 h_g 几乎不变,两者之差 h_fg 因而减小。h_fg 在 0 bar(G) 时约 2,257 kJ/kg,在 10 bar(G) 时约 1,999 kJ/kg。这就是提供相同热量时高压蒸汽需要稍多一些的原因。

能查过热蒸汽的数值吗?

不能。本页只涉及饱和状态(饱和水与饱和蒸汽),不包括过热蒸汽表、压缩水(过冷水)和莫里尔图。

最后更新:2026-11-01。